Hanna Instruments HI-99164 is a pH and temperature meter designed for yoghurt analysis. The HI-99164 is supplied with an FC213D probe which is specifically designed to measure the pH in yoghurt products. A crucial factor when producing consistent and quality yoghurt is monitoring the pH. Yoghurt producers have to ensure the fermentation continues at the predetermined pH level so their yoghurt remains consistent in terms of flavour, texture and aroma.
Benefits
- Application-specific electrode
- Automatic temperature compensation (ATC)
- Stability indicator for accurate data recording
- Battery-powered
- DIN connection
- Simultaneous pH and temperature measurements on a large dual-line LCD display
- User-friendly two-button design
- Application-specific probe
- Durable IP67 waterproof casing
- Watertight probe connection
- Probe condition indicator
- Automatic pH calibration at one or two points within two memorized buffer sets (standard or NIST)
- On-screen calibration tags
- mV of pH measurement for electrode check
- Selectable temperature unit (℃ or deg. F)
- Auto-off function
- Battery life indication and low battery detection
What's included with the meter:
- FC213D pH electrode with internal temperature sensor
- HI-70004 pH 4.01 buffer sachet
- HI-70007 pH 7.01 buffer sachet
- HI-700643 electrode cleaning solution sachets (2)
- Alkaline batteries: 1.5V AAA x 3
- Rugged carrying case
- Instruction manual
The HI-99164 has a split-level LCD display to show both pH and temperature readings, battery percentage, stability and calibration instructions. This meter has an automatic calibration at one or two points with two sets of buffers. The internal temperature sensor in the FC2133 electrode automatically compensates for temperature variations in all calibrations and measurements. The FC2133 has a conical sensing tip for easy penetration into semi-solids and emulsions. It has been designed to prevent clogging, ensure a fast response and a stable reading.
Model | HI-99164 |
pH range |
-2.0 to 16.00 pH |
pH Resolution |
0.01 pH |
pH Accuracy |
±0.02 pH |
Calibration |
automatic, one or two-point selectable buffer set standard pH 4.01, 7.01, 10.01 or NIST pH 4.01, 6.86, 9.18 |
Temperature Compensation |
automatic from -5.0 to 105.0℃ |
Temperature Range |
-5.0 to 105.0?C |
Temperature Resolution |
0.1?C |
Accuracy |
±0.5℃ (up to 60℃); ±1.0℃ (outside) |
IP Rating |
IP67 |
Battery Type / Life |
3 x 1.5V AAA / approx. 1200 hours of continuous use |
Environment |
0 to 50?C; RH max 100% |
Dimensions(WxDxH) |
152 x 58 x 30 mm |
Weight |
205g |