BINDER FD23 heating oven features fully homogeneous temperature distribution, quick dynamics and a powerful fan. Designed for use when fast drying and sterilization is required. BINDER drying chambers are renowned for their high quality and reliability.
Benefits
- 20L capacity
- Temperature range: +5 ℃ above ambient temperature to +300 ℃
- APT.line™ preheating chamber technology
- Forced convection
- Adjustable exhaust air flap
- Controller with timer functions
- 2 chrome-plated racks
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- Uniform drying conditions thanks to APT.line™ technology
- Identical test conditions throughout the chamber interior independent of sample size and quantity
- Outstanding thermal insulation saves operation costs
Technical Specifications
Designation |
FD023-230V*
|
Option model |
Standard |
Order number |
9010-0194 |
Data |
Serie |
FD |
Performance Data Temperature |
Heating-up time to 150 ℃ [min] |
25 |
Recovery time after 30 seconds door open at 150 ℃ [min] |
6 |
Temperature fluctuation at 150 ℃ [± K] |
0.3 |
Temperature range +5 ℃ above ambient temperature to |
300 ℃ |
Temperature variation at 150 ℃ [± K] |
2.5 |
Air change data |
Air change (approx.) at 150 ℃ [x/h] |
64 |
Electrical data |
Nominal power [kW] |
0.8 |
Phase (Nominal voltage) |
1~ |
Power frequency [Hz] |
50/60 |
Rated Voltage [V] |
230 |
Unit fuse [A] |
10 |
Doors |
Unit doors |
1 |
Housing dimensions, not incl. fittings and connections |
Depth net [mm] |
520 |
Height net [mm] |
495 |
Width net [mm] |
435 |
Internal Dimensions |
Depth [mm] |
300 |
Height [mm] |
330 |
Width [mm] |
222 |
Measures |
Interior volume [L] |
20 |
Load per rack [kg] |
12 |
Net weight of the unit (empty) [kg] |
27 |
Permitted load [kg] |
25 |
Wall clearance back [mm] |
160 |
Wall clearance sidewise [mm] |
100 |
Environment-specific data |
Energy consumption at 150 ℃ [Wh/h] |
300 |
Fixtures |
Number of shelves (std./max.) |
2/4 |
*All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 ℃ ±3 ℃ and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.