Grant PCH-1/PCH-2/PCH-3 personal benchtop cooler/heaters are ideal for laboratory applications requiring cooling and heating in microtubes within the temperature setting range of – 10℃ to +100℃. The PCH cooler/heaters enable a stable temperature to be maintained during room temperature fluctuations.
- PCH-1 - 12x1.5 ml plus 20x0.5 ml tubes
- PCH-2 - 20x1.5 ml tubes
- PCH-3 - 20x2 ml microtubes
The ingenious block construction, combined with a powerful Peltier module, produces very rapid cooling and heating for a swift change of application and increased flexibility. In addition, the Peltier effect produces efficient cooling and heating for small thermal loads without the use of a refrigeration system. The dry temperature control system maintains a clean working environment, reducing the chance of contamination or sample dilution. A Peltier system, without the vibration of refrigeration or the turbulence of a water bath, is also ideal for all incubations where stable conditions are critical.
Benefits
- Cooling/heating setting range from – 10ºC to 100℃, with very rapid cool down and heat-up times
- Stability ± 0.1℃, uniformity ±0.25℃ at 37℃
- Convenient integral reaction timer with audible alarm
- Dry temperature control system maintains a clean and vibration-free working environment
- A 2-line LCD display clearly indicates both set and actual values for temperature and time. Works in combination with simple push buttons for easy set-up.
- Flexible tube sizes and rapid heat-up/cool-down times enables swift change of application
The PCH is a very effective tool for DNA sample preparation for denaturing electrophoresis. The exceptionally rapid heat up enables the denaturation temperature of 95℃ to be reached swiftly, the timer will signify denaturation time-up, and the samples can be rapidly cooled again ready to load the gels.
Applications
- Life science – storing frozen restriction enzymes, nick translations, ligation reactions, restriction digests, protein solubilisation for PAGE, warm incubation of microcentrifuge tubes for hybridisation, enzyme reactions and deactivations.
- Clinical – cooling blood samples prior to coagulation testing.
Specifications
|
PCH-1
|
PCH-2
|
PCH-3
|
Dimensions (hxdxw) |
165x260x240mm |
165x260x240mm |
165x260x240mm |
Temperature range |
-10 to 100℃ |
-10 to 100℃ |
-10 to 100℃ |
Temperature control range |
Ambient -30 to 100℃ |
Ambient -30 to 100℃ |
Ambient -30 to 100℃ |
Stability |
0.1℃ |
0.1℃ |
0.1℃ |
Setting resolution |
0.1℃ |
0.1℃ |
0.1℃ |
Block Dimensions |
100x110mm |
100x110mm |
100x110mm |
Heat up time – 25ºC to 37ºC ºC/min |
3 ºC/min |
3 ºC/min |
3 ºC/min |
25ºC to 100ºC ºC/min |
16 ºC/min |
16 ºC/min |
16 ºC/min |
Cool down time 100ºC to -10ºC ºC/min |
28 ºC/min |
28 ºC/min |
28 ºC/min |
25ºC to -10ºC ºC/min |
21 ºC/min |
21 ºC/min |
21 ºC/min |
Capacity |
12x1.5 plus 20x0.5ml |
20x1.5ml |
20x2.0ml |
Display |
2 linex16 character LCD |
2 linex16 character LCD |
2 linex16 character LCD |
Timer |
1 minute to 96 hours/non-stop |
1 minute to 96 hours/non-stop |
1 minute to 96 hours/non-stop |
External power supply |
Input AC 120-230V, 50/60Hz Output DC 12V |
Input AC 120-230V, 50/60Hz Output DC 12V |
Input AC 120-230V, 50/60Hz Output DC 12V |
Power consumption – 230V |
55W (4.4A) |
55W (4.4A) |
55W (4.4A) |
Power consumption – 120V |
|
|
|
Input voltage |
12V dc |
12V dc |
12V dc |
Weight |
3.2kg |
3.2kg |
3.2kg |